11.6. Removal and installation of the generator

Adjustment of a tension of a belt of the drive of the generator

Contact rings of the generator


 PERFORMANCE ORDER

  1. Disconnect a wire from the minus plug of the battery.
  2. Remove the air filter and, depending on a complete set, take away the conditioner compressor, without disconnecting a tube.
  3. Remove a lock spring and an otstykuyta the multicontact socket from the generator.
  4. Weaken nuts and bolts of fastening of the generator and adjustment of a tension of a belt of the drive, and then give the generator to the block of cylinders.
  5. Take off a drive belt from a generator pulley.
  6. Turn off a nut of a hinged bolt and remove a crossing point of grounding of the generator on weight.
  7. Remove bolts of fastening and adjustment together with washers, and then remove the generator.
  8. Installation is made as it should be, the return to removal. Adjustment of a tension of a belt of the drive is carried out by turn of an adjusting bolt. Check an inhaling of bolts of fastening of an arm of the generator.