11.8. Removal, survey and installation of brushes of the generator

 PERFORMANCE ORDER

  1. Disconnect a wire from the minus plug of the battery.
  2. Remove the air filter and, depending on a complete set, take away the conditioner compressor, without disconnecting a tube. Depending on model it can be necessary to remove the generator.
  3. Unscrew screws of fastening and remove a box of the regulator of tension and brushes of a back part of the generator.
  4. If height of any of brushes is less minimum (5 mm), unsolder wires of conclusions and remove brushes and springs.
  5. Wipe contact rings of the generator with the fabric moistened with gasoline. If they are strongly polluted, smooth out them a fine-grained skin (10-M40) and wipe with fabric.