- Disconnect a wire from the minus plug of the battery.
- Remove the air filter and, depending on a complete set, take away the conditioner compressor, without disconnecting a tube. Depending on model it can be necessary to remove the generator.
- Unscrew screws of fastening and remove a box of the regulator of tension and brushes of a back part of the generator.
- If height of any of brushes is less minimum (5 mm), unsolder wires of conclusions and remove brushes and springs.
- Wipe contact rings of the generator with the fabric moistened with gasoline. If they are strongly polluted, smooth out them a fine-grained skin (10-M40) and wipe with fabric.
|
|