2.4.2.9. Check of electromagnetic locking valves

 PERFORMANCE ORDER

  1. At the included ignition green wires with a yellow strip of sockets of electromagnetic locking valves have to be energized (the brown wire is "mass").
  2. Separate the plug socket of the electromagnetic locking valve and again connect it: if the valve is serviceable, then at the same time the click has to be heard.
  3. Check a condition of sealing cuffs of valves and replace them in case of damage.